{"product_id":"hollyland-spares-db25-male-to-db15-male-tally-cable-for-wireless-tally-system","title":"Hollyland Spares - DB25 Male to DB15 Male Tally Cable (for Wireless Tally System)","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows stronger enable-updated-hr-color\" id=\"model-response-message-contentr_f7be8305c16a568b\" dir=\"ltr\"\u003e\n\u003cp id=\"p-rc_888ce2655b6cf64b-239\"\u003e\u003cspan class=\"citation-469\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-469\"\u003eHollyland DB25 Male to DB15 Male Tally Cable (Model: HL-TCB02)\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-469\"\u003e is an official OEM interface adapter configured specifically for the \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-469\"\u003eHollyland Wireless Tally System\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-469 citation-end-469\"\u003e.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the standard DB15 female variant maps incoming auxiliary breakout wiring harnesses, this \u003cb\u003eDB15 Male\u003c\/b\u003e configuration serves as a direct device-to-device connector. It links the parallel tally output framework of native broadcast hardware straight into the main database tracking array of your Hollyland Wireless Tally Station box.\u003c\/p\u003e\n\u003ch3\u003eUnderstanding the Physical Pin Form Factors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDB25 Male Terminal (Tally Station Side):\u003c\/b\u003e Connects firmly into the 25-pin female parallel matrix terminal block mounted on the back panel of the master Wireless Tally base station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDB15 Male Terminal (Switcher Output Side):\u003c\/b\u003e Features a standard-density \u003cb\u003e15-pin profile arranged in 2 rows (8 pins over 7 pins)\u003c\/b\u003e with outward-facing pins. It plugs directly into video switchers featuring native female DB15 parallel tally outputs without the need for an intermediate adapter or gender changer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Hardware \u0026amp; Signal Routing Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLow-Voltage Parallel Relay Mapping:\u003c\/b\u003e Built to carry low-voltage dry contact relay closures without operational lag. The millisecond the master video switcher toggles a line to Program (Live) or Preview (Next Up), the specific circuit completing through the HL-TCB02 cable path alerts the base station to update your remote camera lamp colors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_888ce2655b6cf64b-240\"\u003e\u003cb\u003eDirect Switcher Compatibility:\u003c\/b\u003e\u003cspan class=\"citation-468\"\u003e Specifically engineered to bridge communication protocols natively with well-known broadcast hardware utilizing this exact output profile—such as select \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-468\"\u003ePanasonic AW-HSW10\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-468\"\u003e or \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-468\"\u003ePanasonic AV-HS410MC\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-468 citation-end-468\"\u003e vision mixers.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIndustrial Strain Relief \u0026amp; Shielding:\u003c\/b\u003e Fabricated with heavy-duty molded PVC connector backshells equipped with captive thumb-locking screw sets to lock into place behind tight, high-traffic tech decks. The core is protected with premium foil shielding to keep parallel data paths isolated from adjacent electromagnetic interference (EMI) radiating from studio power grids or server clusters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specifications Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOfficial Model SKU\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHL-TCB02 (Part Number: 191460005831)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePrimary System Family\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHollyland Wireless Tally System Base Stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eConnector Side A Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × DB25 Male Terminal (Standard D-Sub Parallel Layout)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eConnector Side B Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × DB15 Male Terminal (Standard-Density 2-Row Pattern)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePhysical Cable Length\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.92 feet (\u003cb\u003e1.5 Meters\u003c\/b\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSignal Core Design\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePure Analog Parallel Relay \/ Voltage Ground Closures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eColor Configuration Finish\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBroadcast Matte Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNet Component Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLightweight and flexible at 6.9 oz (\u003cb\u003e195 grams\u003c\/b\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cb\u003eThe 2-Row vs. 3-Row Density Rule:\u003c\/b\u003e Always double-check the configuration of your production switcher's tally out block before seating the cable. A standard \u003cb\u003eDB15 Male\u003c\/b\u003e (this product) features a wider shell framing \u003cb\u003e2 rows\u003c\/b\u003e of pins. A high-density \u003cb\u003eHDB15\u003c\/b\u003e model features a tighter footprint with \u003cb\u003e3 rows\u003c\/b\u003e of micro-pins (styled like a legacy VGA monitor hookup). Forcing incorrect pin row densities together will permanently crush the copper contacts.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e","brand":"Hollyland","offers":[{"title":"Default Title","offer_id":52073222963502,"sku":"S-HOL-TCB02","price":496.8,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0801\/0157\/2910\/files\/S-HOL-TCB02_image1_d7de781e-db8f-4901-b556-a690e9290bd5.jpg?v=1782131267","url":"https:\/\/shopvisuals.tv\/products\/hollyland-spares-db25-male-to-db15-male-tally-cable-for-wireless-tally-system","provider":"ShopVisuals.tv","version":"1.0","type":"link"}