{"product_id":"hollyland-spares-db25-male-to-db9-male-tally-cable-for-wireless-tally-system","title":"Hollyland Spares - DB25 Male to DB9 Male Tally Cable (for Wireless Tally System)","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows stronger enable-updated-hr-color\" id=\"model-response-message-contentr_089e0aedb94855d7\" dir=\"ltr\"\u003e\n\u003cp\u003eThe \u003cb\u003eHollyland DB25 Male to DB9 Male Tally Cable (Model: HL-TCB04)\u003c\/b\u003e is an official OEM interface adapter designed exclusively for the \u003cb\u003eHollyland Wireless Tally System\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp\u003eWhile the female DB9 variant (HL-TCB05) connects to switchers that feature an outward-facing male port, this \u003cb\u003eDB9 Male\u003c\/b\u003e version functions as a direct interconnect for broadcast switchers, camera control units (CCUs), and vision mixers equipped with native female DB9 tally outputs. It accurately carries low-voltage parallel dry contact closures to change the colors of your remote, wireless on-camera tally lamps.\u003c\/p\u003e\n\u003ch3\u003eUnderstanding the Component Interface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDB25 Male Terminal (Tally Station Side):\u003c\/b\u003e Standard 25-pin D-Sub connector that plugs into the master parallel tally input matrix on the rear panel of the main Hollyland Wireless Tally base station box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDB9 Male Terminal (Switcher Output Side):\u003c\/b\u003e Standard 9-pin connector (also called a DE-9 plug) featuring an outward-facing pin arrangement inside a 2-row footprint (5 pins over 4 pins). It hooks directly into the switcher's female tally port without requiring any intermediary adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Hardware Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eZero-Latency Dry Contact Switching:\u003c\/b\u003e Custom-wired to safely pass low-voltage parallel relay ground signals. The moment an operator switches a source into the Program or Preview bus, the circuit completes instantly, giving you instantaneous red\/green tally updates on set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHigh-Density Copper \u0026amp; EMI Shielding:\u003c\/b\u003e Fabricated with high-grade multi-conductor copper wiring wrapped inside a dense electromagnetic interference (EMI) shield. This prevents signal crosstalk or false tally triggers caused by studio power lines, lighting ballasts, or heavy-duty server racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCaptive Screw Mechanical Locks:\u003c\/b\u003e Both the DB25 and DB9 connector heads are molded from high-impact PVC and equipped with integrated metal thumbscrews. This locks the cable tightly into your production station, completely preventing accidental signal disconnects from physical cable pulls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specifications Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOfficial Model SKU\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHL-TCB04 (Part Family: S-HOL-TCB04)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePrimary System Family\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHollyland Wireless Tally System Base Stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eConnector Side A Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × DB25 Male Terminal (Parallel D-Sub Format)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eConnector Side B Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × DB9 Male Terminal (Standard 2-Row Pin Layout)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePhysical Cable Length\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.92 feet (\u003cb\u003e1.5 Meters\u003c\/b\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSignal Transmission Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePure Analog Parallel Relay \/ Voltage Ground Closures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eColor Configuration Profile\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBroadcast Matte Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNet Component Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 6.4 oz (\u003cb\u003e181 grams\u003c\/b\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cb\u003ePin Layout Setup Check:\u003c\/b\u003e If you plug this cable into your switcher and find that the camera channel indicators are mixed up (e.g., Camera 1 lights up when Camera 3 is selected), you don't need to cut or rewire the harness. Go to the master Hollyland Wireless Tally Station's front panel and open the \u003cb\u003eSequence Learning\u003c\/b\u003e menu. This software feature allows you to digitally remap the data incoming from the DB9 pins inside the station's memory, ensuring your camera lines match perfectly across your entire control layout.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e","brand":"Hollyland","offers":[{"title":"Default Title","offer_id":52073223323950,"sku":"S-HOL-TCB04","price":496.8,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0801\/0157\/2910\/files\/S-HOL-TCB04_image1_c894ea5e-b0a6-4095-be25-910b655eabf2.jpg?v=1782131224","url":"https:\/\/shopvisuals.tv\/products\/hollyland-spares-db25-male-to-db9-male-tally-cable-for-wireless-tally-system","provider":"ShopVisuals.tv","version":"1.0","type":"link"}